A BAA Covers the Model. PHI Lives in Six More Places.
In a healthcare RAG system, patient data touches seven layers. NonStop builds a control into each one.
Identifiers the task does not need are stripped before the model call.
Every query is tied to a named user and role.
Search returns only what that user is allowed to see.
Runs under a BAA or inside your own environment.
Every claim cites its source, with human review where risk calls for it.
PHI is redacted before anything is logged.
Cases are de-identified before they enter any dataset.
Embeddings count too. Researchers recovered 92% of short text inputs exactly from their embeddings (Morris et al., EMNLP 2023).
What Healthcare Teams Get From a Private LLM Build
Answers Clinicians Can Verify
Every answer links to the guideline, SOP or prior case it came from.
Search That Respects Permissions
Permission-aware retrieval mirrors your source systems, so nobody sees records they should not.
PHI Stays Where You Choose
Cloud model service, vendor API, your own cloud account or on-premise.
Evidence for Your Privacy Officer
Audit trails, redacted logs and documented controls, mapped to 45 CFR §164.312.
Results From NonStop Healthcare AI Builds
Where to Run Your LLM With PHI
On-Premise
Open-weight model and vector search on your own hardware.
Self-Hosted in Your Cloud
Open-weight model in your own AWS, Azure or Google Cloud account.
Cloud Model Service
Amazon Bedrock, Azure OpenAI or Google Cloud Agent Platform (Vertex AI), under the provider's BAA.
Model Vendor API
Anthropic's Claude API or OpenAI's API, under the vendor's BAA for eligible features.
Every path still needs a risk analysis and Security Rule controls. BAA scope varies by service and feature, so NonStop confirms it before any PHI moves.
How a HIPAA LLM Project Works With NonStop
AI Architecture Review
45 minutes. Bring one question you want an LLM to answer. A senior engineer maps where PHI would flow.
PHI Boundary and Plan
Hosting path, retrieval design, evaluation approach and the controls each layer needs, in a phased plan.
Build, Test, Hand Over
Engineers embed on-site in the US or work remotely, test on real workflows, and hand over the system with full IP ownership.
Healthcare RAG Use Cases by Team
Genomics Labs
Search your own variant interpretation history, as in GENVAR, deployed on-premises.
Diagnostic Labs
Read requisitions and answer SOP questions without patient data leaving the lab.
Health Systems and Health Tech
Guideline and payer policy search, and prior authorization support with clinician sign-off.
Pharma and Biotech
Search protocols, SOPs, regulatory documents and PubMed with source citations.
HIPAA LLM Readiness Checklist
Score any LLM build against it, including ours.
- A signed BAA covers the model service, and the features or endpoints in use are in scope.
- Every other vendor that stores PHI, such as the vector database, has a BAA or runs inside your environment.
- Embeddings made from PHI are encrypted and access-controlled.
- Retrieval enforces each user's permissions from the source system.
- Separate indexes keep tenants or client labs apart.
- PHI detection runs on inputs and outputs.
Show all 12
- Logs redact PHI and follow a set retention period.
- Every answer cites its source.
- Test and training data are de-identified under 45 CFR §164.514(b).
- Red-team tests cover prompt injection, including instructions hidden in retrieved documents.
- Model versions are pinned, and changes are tested against agreed acceptance criteria.
- A named person reviews output wherever clinical or quality risk calls for it.
